Remote control commands
R&S
®
RTO6
2434User Manual 1801.6687.02 ─ 05
Parameters:
<Slope> POSitive | NEGative | EITHer
*RST: POSitive
Usage: Asynchronous command
24.18.4.3 Width trigger
See also:
●
TRIGger<m>:
PARallel:WIDTh:EXPRession[:DEFine] on page 2433
TRIGger<m>:PARallel:WIDTh:POLarity..........................................................................2434
TRIGger<m>:PARallel:WIDTh:RANGe........................................................................... 2434
TRIGger<m>:PARallel:WIDTh:WIDTh............................................................................ 2434
TRIGger<m>:PARallel:WIDTh:DELTa.............................................................................2435
TRIGger<m>:PARallel:WIDTh:POLarity <Polarity>
Sets the polarity of a pulse. When triggering on a positive pulse, the trigger event
occurs on the high to low transition of the pulse if the timing condition is true. When
triggering on a negative pulse, the trigger event occurs on the low to high transition of
the pulse if the timing condition is true.
Parameters:
<Polarity> POSitive | NEGative | EITHer
*RST: POSitive
Usage: Asynchronous command
TRIGger<m>:PARallel:WIDTh:RANGe <RangeMode>
Selects how the range of a pulse width is defined:
Parameters:
<RangeMode> WITHin | OUTSide | SHORter | LONGer
WITHin | OUTSide
Pulses inside or outside a given time range. The time range
Width
±
Delta is defined by TRIGger<m>:PARallel:WIDTh:
WIDTh and TRIGger<m>:PARallel:WIDTh:DELTa.
SHORter | LONGer
Pulses shorter or longer than a given width defined by
TRIGger<m>:PARallel:WIDTh:WIDTh
*RST: WITHin
Usage: Asynchronous command
TRIGger<m>:PARallel:WIDTh:WIDTh <Width>
Sets the limit for the pulse width.
Mixed signal option (MSO, R&S RT