Remote control commands
R&S
®
RTO6
1326User Manual 1801.6687.02 ─ 05
STOP
Stops the running acquistion.
Usage: Event
Asynchronous command
24.8.2 Time base
TIMebase:SCALe
.........................................................................................................1326
TIMebase:RANGe........................................................................................................1327
TIMebase:DIVisions?....................................................................................................1327
TIMebase:HORizontal:POSition.....................................................................................1327
TIMebase:REFerence...................................................................................................1327
TRIGger<m>:OFFSet:LIMited........................................................................................1328
AUToscale...................................................................................................................1328
ACQuire:POINts:AUTO.................................................................................................1328
ACQuire:POINts:AADJust.............................................................................................1329
ACQuire:POINts:MAXimum...........................................................................................1329
ACQuire:POINts:ARATe?..............................................................................................1329
ACQuire:SRATe........................................................................................................... 1329
ACQuire:SRReal..........................................................................................................1330
ACQuire:RESolution.....................................................................................................1330
ACQuire:POINts[:VALue].............................................................................................. 1330
TIMebase:ROLL:ENABle.............................................................................................. 1331
TIMebase:ROLL:STATe?...............................................................................................1331
TIMebase:ROLL:MTIMe................................................................................................1331
TIMebase:SCALe <TimeScale>
Sets the horizontal scale - the time per division on the x-axis - for all channel and math
waveforms.
The setting accuracy depends on the current resolution (sample rate).
●
No interpolation:
The resolution is an integer multiple of the ADC sample rate.
●
With interpolation:
Any value for the horizontal scale can be set.
Parameters:
<TimeScale> Range: 25E-12 to 10000 (RTO, RTP) | 5000 (RTE)
Increment: 1E-12
*RST: 10E-9
Default unit: s/div
Usage: Asynchronous command
Acquisition and setup