Protocol analysis
R&S
®
RTO6
774User Manual 1801.6687.02 ─ 05
Data
Searches for a data pattern or a data word range. The setting is available for all
"Extended Register"
command sequences, which can transfer more than one data
frame.
The data settings are the same as in the RFFE trigger setup, see "Data"
on page 767.
Remote command:
SEARch:TRIGger:RFFE:DATA:DCON on page 2079
SEARch:TRIGger:RFFE:DATA:DMIN on page 2080
SEARch:TRIGger:RFFE:DATA:DMAX on page 2080
Index
Defines which data frames are relevant for the search. The setting is available for all
Extended Register command sequences, which can transfer more than one data
frame. To search for any data byte that fulfills the data pattern settings, set the index to
XX.
Remote command:
SEARch:TRIGger:RFFE:DATA:ICONdition on page 2079
SEARch:TRIGger:RFFE:DATA:IMIN on page 2080
SEARch:TRIGger:RFFE:DATA:IMAX on page 2080
Data
Defines the pattern of the interrupt identification sequence, which consists of interrupt
slots 15 to 0. The setting is only available for "Interrupt Summary and Notification"
command sequence.
Remote command:
SEARch:TRIGger:RFFE:INTerrupt on page 2080
Error conditions
Defines which error conditions are relevant for the search.
Remote command:
SEARch:TRIGger:RFFE:ERRor:LENGth on page 2081
SEARch:TRIGger:RFFE:ERRor:PARity on page 2081
SEARch:TRIGger:RFFE:ERRor:SSC on page 2081
SEARch:TRIGger:RFFE:ERRor:GAP on page 2082
SEARch:TRIGger:RFFE:ERRor:VERSion on page 2082
13.17.6.2 RFFE search results
To get search results, "Enable" the search. You can minimize, shift or close the search
dialog.
The search results are listed in the search result table and marked in the waveform by
blue lines.
For an introduction to search results, see:
●
Chapter 11.1.2, "Search results", on page 420
●
Chapter 11.4.2, "Display zoom settings", on page 440
RFFE (option R&S RT