Remote control commands
R&S
®
RTO6
2080User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:RFFE:SADD:MIN <SearchName>,<SIDMin>
SEARch:TRIGger:RFFE:SADD:
MIN? <SearchName>
SEARch:TRIGger:RFFE:ADDRess:
MIN <SearchName>,<AddressMin>
SEARch:TRIGger:RFFE:ADDRess:MIN? <SearchName>
SEARch:TRIGger:RFFE:BCOunt:MIN <SearchName>,<ByteCountMin>
SEARch:TRIGger:RFFE:BCOunt:MIN? <SearchName>
SEARch:TRIGger:RFFE:DATA:IMIN <SearchName>,<DataIndexMin>
SEARch:TRIGger:RFFE:DATA:IMIN? <SearchName>
SEARch:TRIGger:RFFE:DATA:DMIN <SearchName>,<DataPatternMin>
SEARch:TRIGger:RFFE:DATA:DMIN? <SearchName>
Specifies a pattern, or sets the the start value of a pattern range.
Parameters:
<DataPatternMin> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
String parameter
Example: See "Searching RFFE data" on page 1274
SEARch:TRIGger:RFFE:SADD:MAX <SearchName>,<SIDMax>
SEARch:TRIGger:RFFE:SADD:MAX? <SearchName>
SEARch:TRIGger:RFFE:ADDRess:MAX <SearchName>,<AddressMax>
SEARch:TRIGger:RFFE:ADDRess:MAX? <SearchName>
SEARch:TRIGger:RFFE:BCOunt:MAX <SearchName>,<ByteCountMax>
SEARch:TRIGger:RFFE:BCOunt:MAX? <SearchName>
SEARch:TRIGger:RFFE:DATA:IMAX <SearchName>,<DataIndexMax>
SEARch:TRIGger:RFFE:DATA:IMAX? <SearchName>
SEARch:TRIGger:RFFE:DATA:DMAX <SearchName>,<DataPatternMax>
SEARch:TRIGger:RFFE:DATA:DMAX? <SearchName>
Sets the the end value of an range if the corresponding condition is set to INRange or
OORange. See SEARch:TRIGger:RFFE:...:CON
Parameters:
<DataPatternMax> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
String parameter
SEARch:TRIGger:RFFE:INTerrupt <SearchName>,<Interrupt>
SEARch:TRIGger:RFFE:INTerrupt? <SearchName>
Defines the pattern of the interrrupt identification sequence, which consists of interrupt
slots 15 to 0.
Protocols