Power analysis (option R&S RTO6-K31)
R&S
®
RT
O6
1156User Manual 1801.6687.02 ─ 05
19.4.2.1 Dynamic on resistance results
The results of "Dynamic on Resistance"
measurements are provided in two ways:
The diagram shows the graphical presentation of:
the voltage waveform
the current waveform
The result box displays the dynamic on resistance value.
To measure and display the dynamic on resistance, the instrument uses the following
measurements and waveforms:
"MG 5" to measure the amplitude of the voltage
"MG 6"
to measure the amplitude of the voltage
"MG 7" to measure the amplitude of the current
"MG 8" to measure the amplitude of the current
"Cu 1 " Cursor 1 to measure gate ["t
0
" ,"t
1
"]
"Cu 2 " Cursor 2 to measure gate ["t
2
" ,"t
3
"]
The used resources are listed in the "Details" tab. See also: Chapter 19.2.3, "Details
tab", on page 1135.
The dynamic on resistance displayed as the result is defined as:
The points "t
0
" , "t
1
", "t
2
" and "t
3
" are defined by the cursor lines displayed in the result
diagram of the measurement. Y
ou can move the cursor lines to define another area of
interest.
The following remote commands are used for handling the measurement results:
POWer:
DONRes:RESult:RESistance? on page 2536
POWer:DONRes:GATE<m>:STARt on page 2536
POWer:DONRes:GATE<m>:STOP on page 2536
POWer:DONRes:REPort:ADD on page 2536
19.4.2.2 Configuring dynamic on resistance
For details of the configuration settings, see Chapter 19.4.2.3, "Dynamic on resistance
settings", on page 1158.