Remote control commands
R&S
®
RTO6
1893User Manual 1801.6687.02 ─ 05
Parameters:
<FESError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:FSSerror <SearchName>,<FSSError>
SEARch:TRIGger:FLXRay:FSSerror? <SearchName>
Searches for an error in a Frame Start Sequence(FSS). FSS follows the Transmission
Start Sequence (TSS) at the beginning of each frame.
Parameters:
<FSSError>
ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:HCRCerror <SearchName>,<CRCHeaderError>
SEARch:TRIGger:FLXRay:HCRCerror
?
<SearchName>
Searches for an error in the Cyclic Redundancy Check of the header data (mainly
frame ID and payload length).
Parameters:
<CRCHeaderError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:PCRCerror <SearchName>,<CRCPayloadError>
SEARch:TRIGger:FLXRay:PCRCerror?
<SearchName>
Searches for error in the Cyclic Redundancy Check of the payload data.
Parameters:
<CRCPayloadError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
24.17.10.5 Search results
The search on decoded FlexRay data returns the same results as the queries for
decode results.