Remote control commands
R&S
®
RTO6
2019User Manual 1801.6687.02 ─ 05
T100
Sets the thresholds to the default values for 10BASE-T
(100 meters): upper threshold to 0.75 V
, lower threshold to
-0.75
V
TX0
Sets the thresholds to the default values for 100BASE-TX
(0 meters): upper threshold to 0.5 V, lower threshold to -0.5 V
TX100
Sets the thresholds to the default values for 100BASE-TX
(100 meters): upper threshold to 0.35 V, lower threshold to
-0.35 V
MANual
Allows to set individual threshold voltage levels
*RST: T0
BUS<m>:ETHernet:BITRate <BitRateV
alue>
Sets the bit rate value that defines the transmission speed in bits per second.
Suffix:
<m>
.
1..4
Parameters:
<BitRateV
alue> Range: 10000 to 150000000
Increment: 1000
*RST: 10000000
Default unit: bps
24.17.16.2 Trigger
The trigger suf
fix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
TRIGger<m>:SOURce[:SELect] is set to SBUS.
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:ETHernet:TYPE....................................................................................... 2020
TRIGger<m>:ETHernet:PATTern....................................................................................2020
TRIGger<m>:ETHernet:ERRor:CRC..............................................................................2020
TRIGger<m>:ETHernet:ERRor:LENGth..........................................................................2021
TRIGger<m>:ETHernet:ERRor:PREamble......................................................................2021
TRIGger<m>:ETHernet:FRAMe:CCONdition...................................................................2021
TRIGger<m>:ETHernet:FRAMe:CMAX.......................................................................... 2022
TRIGger<m>:ETHernet:FRAMe:CMIN............................................................................2022
TRIGger<m>:ETHernet:FRAMe:DCONdition...................................................................2022