Remote control commands
R&S
®
RTO6
1603User Manual 1801.6687.02 ─ 05
MTESt:EYEMask:HPOSition <MaskT
estName>,<PatOf
fsetX>
MTESt:EYEMask:HPOSition? <MaskTestName>
Sets the horizontal (time) value of the eye shape enter and thus defines the horizontal
position of the eye shape on the display.
Parameters:
<PatOffsetX> Range: -100 to 100
Increment: 0.01
*RST: 0
Default unit: s
Parameters for setting and query:
<MaskTestName> String with the name of the mask test
Usage: Asynchronous command
MTESt:EYEMask:VPOSition <MaskTestName>,<PatOf
fsetY>
MTESt:EYEMask:VPOSition? <MaskTestName>
Sets the vertical (voltage) value of the eye shape enter and thus defines the vertical
position of the eye shape on the display.
Parameters:
<PatOffsetY> Range: -100 to 100
Increment: 0.01
*RST: 0
Default unit: V
Parameters for setting and query:
<MaskTestName> String with the name of the mask test
Usage: Asynchronous command
24.15 Search
Some of the commands in the following chapter are asynchronous. An overlapping or
asynchronous command does not automatically finish executing before the next com-
mand starts executing. If overlapping commands must be executed in a defined order
,
e.g. to avoid wrong measurement results, they must be serviced sequentially.
T
o prevent an overlapping execution of commands, one of the commands *OPC,
*OPC? or *WAI can be used after the command or a command set.
For more information, see:
●
www.rohde-schwarz.com/rc-via-scpi, chapter "Command Sequence and Synchro-
nization"
●
Chapter 24.3, "Programming examples", on page 1259
Search