Remote control commands
R&S
®
RTO6
2055User Manual 1801.6687.02 ─ 05
Usage: Query only
SEARch:RESult:MDIO:WCOunt? <SearchName>
Returns the word count within the search result.
Query parameters:
<SearchName>
Return values:
<FrameCount> Range: 0 to 100000
Increment: 1
*RST: 0
Usage: Query only
24.17.18 RFFE (option R&S RTO6-K550)
For programming examples, see Chapter 24.3.7.1, "RFFE (option R&S RTO6-K550)",
on page 1273.
24.17.18.1 Configuration
In all BUS<m>:RFFE commands, the suffix <m> selects the serial bus.
For programming examples, see "Configuring RFFE bus" on page 1273.
BUS<m>:RFFE:CLOCk:SOURce...................................................................................2055
BUS<m>:RFFE:DATA:SOURce.....................................................................................2056
BUS<m>:RFFE:PRESet............................................................................................... 2056
BUS<m>:RFFE:COUPling............................................................................................ 2056
BUS<m>:RFFE:DATA:THReshold:HIGH.........................................................................2056
BUS<m>:RFFE:DATA:THReshold:LOW......................................................................... 2057
BUS<m>:RFFE:DATA:THReshold:HYSTeresis................................................................2057
BUS<m>:RFFE:CLOCk:THReshold:HIGH...................................................................... 2057
BUS<m>:RFFE:CLOCk:THReshold:LOW.......................................................................2058
BUS<m>:RFFE:CLOCk:THReshold:HYSTeresis............................................................. 2058
BUS<m>:RFFE:GFILter................................................................................................2058
BUS<m>:RFFE:GFWidth.............................................................................................. 2059
BUS<m>:RFFE:MINGap:SELect................................................................................... 2059
BUS<m>:RFFE:MINGap:TIME...................................................................................... 2059
BUS<m>:RFFE:RDMD................................................................................................. 2059
BUS<m>:RFFE:VERSion..............................................................................................2060
BUS<m>:RFFE:CLOCk:SOURce <SourceClock>
Sets the source of the RFFE clock line.
For triggering on a serial bus, analog or digital input channels are required.
Protocols