Remote control commands
R&S
®
RTO6
1410User Manual 1801.6687.02 ─ 05
SHORter
T
riggers on pulses shorter than the given width.
LONGer
T
riggers on pulses longer than the given width.
*RST: WITHin
Usage: Asynchronous command
TRIGger<m>:PATTern:WIDTh[:WIDTh] <Width>
For the ranges "Within"
and "Outside" (defined using TRIGger<m>:PATTern:WIDTh:
RANGe), the width defines the center of a range which is defined by the limits "±Delta"
(see TRIGger<m>:PATTern:WIDTh:DELTa on page 1410).
For the ranges "Shorter" and "Longer", the width defines the maximum and minimum
pulse width, respectively.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<Width> Range:
100E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:PATTern:WIDTh:DELTa <WidthDelta>
Defines a range around the width value specified using TRIGger<m>:PATTern:
WIDTh[:
WIDTh].
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<WidthDelta>
Range: 0 to 432
Increment: 500E-12
*RST: 0
Default unit: s
Usage: Asynchronous command
24.9.13 Serial pattern trigger
The serial pattern trigger is only available for the A-event (Suffix = 1).
T
rigger