Protocol analysis
R&S
®
RTO6
563User Manual 1801.6687.02 ─ 05
Remote command:
BUS<m>:
CMSB:FRAMe<n>:
CELL<o>:FORMat on page 1765
Bit Order
This defines, in which order the bits of a cell's Condition value are evaluated: either the
most significant bit (MSB) or the least significant bit (LSB) first. Since the bit order is
considered for the interpretation of the condition, you should specify MSB or LSB cor-
rectly.
Remote command:
BUS<m>:CMSB:FRAMe<n>:CELL<o>:BITorder on page 1766
Color
Opens a dialog to select the color representation of different cells in the honeycomb
display. Assigning user-selected colors helps to interpret the decode results more
easily.
In the "Adjust Colors" dialog, you can either select one of the predefined colors or
define a new one.
Remote command:
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CRGB on page 1766
Result
This determines which cells shall be displayed in which result columns of the decode
table. No index means that the result is not displayed. The decode table supports three
result columns, which have to be unique for each frame type. For different frame types,
though, the user can define different result columns, to display unrelated information.
Note: To see more than the three selected results, bring up a full list of the states and
values of all cells by activating "Show details" in the decode table dialog.
Remote command:
BUS<m>:CMSB:FRAMe<n>:CELL<o>:CLMN on page 1766
Open or Save XML File
For efficient working and for convenient exchange of frame descriptions, they can both
be loaded ("Open") or saved ("Save" / "Save As...") in XML file format. "Explore..."
opens the SaveXML folder, which is the "Default Path" for saving frame descriptions.
Remote command:
BUS<m>:CMSB:LOAD on page 1767
BUS<m>:CMSB:SAVE on page 1767
13.6.2.4 XML syntax
This chapter explains the required grammar and syntax of XML files, which contain cus-
tom frames and can be loaded or saved. Below is a typical example of such an XML
file:
Custom: Manchester / NRZ (option R&S RT
O6-K510)