EasyManua.ls Logo

R&S RTO6 - 24.15.12 Pattern search conditions

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1623User Manual 1801.6687.02 ─ 05
Parameters:
<HoldTime> Range: -99.999E-9 to 0.1
Increment: 1E-9
*RST: 0
Default unit: s
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:TRIGger:SETHold:STIMe <SearchName>,<SetupTime>
SEARch:TRIGger:SETHold:STIMe
? <SearchName>
Sets the minimum time before the clock edge while the data signal must stay steady
above or below the data level.
The setup time can be negative. In this case, the hold time is always positive. The
setup/hold interval starts after the clock edge (setup time) and ends after the clock
edge (hold time). If you change the negative setup time, the hold time is adjusted by
the intrument.
Parameters:
<SetupTime> Range: -99.999E-9 to 0.1
Increment: 1E-9
*RST: 0
Default unit: s
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
24.15.12 Pattern search conditions
SEARch:TRIGger:PA
TTern:A[:ENABle]...........................................................................1624
SEARch:TRIGger:PATTern:B[:ENABle]...........................................................................1624
SEARch:TRIGger:PATTern:C[:ENABle].......................................................................... 1624
SEARch:TRIGger:PATTern:D[:ENABle].......................................................................... 1624
SEARch:TRIGger:PATTern:A:LOGic...............................................................................1624
SEARch:TRIGger:PATTern:B:LOGic...............................................................................1624
SEARch:TRIGger:PATTern:C:LOGic.............................................................................. 1624
SEARch:TRIGger:PATTern:D:LOGic.............................................................................. 1624
SEARch:TRIGger:PATTern:AB:LOGic............................................................................ 1625
SEARch:TRIGger:PATTern:CD:LOGic............................................................................1625
SEARch:TRIGger:PATTern:ABCD:LOGic........................................................................1625
SEARch:TRIGger:PATTern:MODE.................................................................................1625
SEARch:TRIGger:PATTern:TIMeout:MODE.................................................................... 1626
SEARch:TRIGger:PATTern:TIMeout[:TIME].................................................................... 1626
Search

Table of Contents

Other manuals for R&S RTO6

Related product manuals