R&S RTO6 - 24.17.20.2 Decode results

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
2119User Manual 1801.6687.02 ─ 05
Parameters:
<Polarity> NORMal | INVert
*RST: NORMal
BUS<m>:TBTO:SYMRate <SymbolRate>
Defines the rate of ternary symbols.
Suffix:
<m>
.
1..4
Parameters:
<SymbolRate> Range: 10 to 1500
Increment: 1E-3
*RST: 750
Default unit: MSymb/s
24.17.20.2 Decode results
To show the results on the screen, use the following commands:
BUS<m>:
RESult on page 1671
BUS<m>:TBTO:RESult:FCOunt?...................................................................................2119
BUS<m>:TBTO:RESult:FRAMe<n>:BITRate?.................................................................2120
BUS<m>:TBTO:RESult:FRAMe<n>:CRC?..................................................................... 2120
BUS<m>:TBTO:RESult:FRAMe<n>:DATA?.................................................................... 2120
BUS<m>:TBTO:RESult:FRAMe<n>:DESTaddress?.........................................................2121
BUS<m>:TBTO:RESult:FRAMe<n>:DSYMbol?...............................................................2121
BUS<m>:TBTO:RESult:FRAMe<n>:FTYPe?.................................................................. 2121
BUS<m>:TBTO:RESult:FRAMe<n>:NUMWords?............................................................2122
BUS<m>:TBTO:RESult:FRAMe<n>:SRCaddress?.......................................................... 2122
BUS<m>:TBTO:RESult:FRAMe<n>:SSYMbol?...............................................................2122
BUS<m>:TBTO:RESult:FRAMe<n>:STARt?................................................................... 2123
BUS<m>:TBTO:RESult:FRAMe<n>:STATe?................................................................... 2123
BUS<m>:TBTO:RESult:FRAMe<n>:STOP?....................................................................2124
BUS<m>:TBTO:RESult:FRAMe<n>:TYPE?....................................................................2124
BUS<m>:TBTO:RESult:FRAMe<n>:WORD<o>:TYPE?................................................... 2124
BUS<m>:TBTO:RESult:FRAMe<n>:WORD<o>:VALue?.................................................. 2125
BUS<m>:TBTO:RESult:FCOunt?
Returns the number of decoded frames.
Suffix:
<m>
.
1..4
Selects the serial bus.
Return values:
<FrameCount> Range: 0 to 100000
Increment: 1
*RST: 0
Protocols