EasyManua.ls Logo

R&S RTO6 - 13.13.5 Search on decoded ARINC 429 data

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTO6
711User Manual 1801.6687.02 ─ 05
The color-coding of the various protocol sections and errors simplifies the interpretation
of the visual display
. The decode information condenses or expands, depending on the
horizontal scale. V
arious data formats are available to show the result values.
Decode Results Table
The "Decode results" table contains information about all decoded frames.
Table 13-19: Content of the Decode results table
Column Description
State Overall state of the frame.
Start Time of word start in relation to the trigger point
Stop Time of word stop in relation to the trigger point
Label The value of the label bytes
SDI The state of the SDI bits
DATA All 32 bits of the word.
SSM The state of the SSM bits
Label Name The label name
Data (32 bit) The value of the data bytes
Tools
Press "Display settings" in the "Decode Results"
table to access the "Display" tab.
Remote commands
Remote commands are described in Chapter 24.17.14.3, "Decode results",
on page 1989.
13.13.5
Search on decoded ARINC 429 data
Using the search functionality, you can find various events in the decoded data, the
same events which you also can trigger on. Before you can start the search, you have
to configure the bus correctly and acquire decoded data.
To search on decoded data, set the search "Source" to the serial bus that is configured
for the protocol to be analyzed.
ARINC 429 (option R&S R
T
O6-K530)

Table of Contents