Remote control commands
R&S
®
RTO6
1363User Manual 1801.6687.02 ─ 05
PROBe<m>:SETup:OFFSet:ZADJust <ZroAdjV
al>
set the waveform to zero position. It corrects the ef
fect of a voltage offset or tempera-
ture drift. To set the value by the instrument, use PROBe<m>:SETup:OFFSet:AZERo.
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<ZroAdjVal> Range: -100 to 100
Increment: 0.1
*RST: 0
Default unit: %
Usage: Asynchronous command
Firmware/software: FW 2.50
24.8.7.9 Probe attributes
PROBe<m>:ID:SWVersion?
..........................................................................................1363
PROBe<m>:ID:PRDate?...............................................................................................1363
PROBe<m>:ID:PARTnumber?.......................................................................................1364
PROBe<m>:ID:SRNumber?..........................................................................................1364
PROBe<m>:SETup:CAPacitance?.................................................................................1364
PROBe<m>:SETup:IMPedance?................................................................................... 1364
PROBe<m>:ID:SWVersion?
Queries the version of the probe firmware.
Suffix:
<m>
.
1..4
Selects the input channel.
Return values:
<Softwareversion> Version number in a string.
Usage: Query only
Asynchronous command
PROBe<m>:ID:PRDate?
Queries the production date of the probe.
Suffix:
<m>
.
1..4
Selects the input channel.
Return values:
<ProductionDate> Date in a string.
Acquisition and setup