Remote control commands
R&S
®
RTO6
2255User Manual 1801.6687.02 ─ 05
Parameters:
<HSWordCountMax> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page
1286. The string parameter accepts the bit
value X (don't care).
TRIGger<m>:DPHY
:WCOunt:MIN <HSWordCountMin>
Specifies a word bit pattern, or sets the the start value of a pattern range.
Parameters:
<HSW
ordCountMin> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
24.17.24.3 D-PHY decode results
To show the results on the screen, use the following commands:
●
BUS<m>:
RESult on page 1671
BUS<m>:DPHY:RESult:FCOunt?.................................................................................. 2255
BUS<m>:DPHY:RESult:FRAMe<n>:CS?........................................................................2255
BUS<m>:DPHY:RESult:FRAMe<n>:DATA?.................................................................... 2256
BUS<m>:DPHY:RESult:FRAMe<n>:DTName?............................................................... 2256
BUS<m>:DPHY:RESult:FRAMe<n>:DTYPe?..................................................................2257
BUS<m>:DPHY:RESult:FRAMe<n>:ECC?..................................................................... 2257
BUS<m>:DPHY:RESult:FRAMe<n>:PACKet<o>:IDX?..................................................... 2257
BUS<m>:DPHY:RESult:FRAMe<n>:PACKet<o>:VALue?.................................................2258
BUS<m>:DPHY:RESult:FRAMe<n>:STARt?...................................................................2258
BUS<m>:DPHY:RESult:FRAMe<n>:STATe?...................................................................2258
BUS<m>:DPHY:RESult:FRAMe<n>:STOP?................................................................... 2259
BUS<m>:DPHY:RESult:FRAMe<n>:TYPE?....................................................................2259
BUS<m>:DPHY:RESult:FRAMe<n>:NUMPackets?......................................................... 2260
BUS<m>:DPHY:RESult:FRAMe<n>:VCHannel?............................................................. 2260
BUS<m>:DPHY:RESult:FCOunt?
Returns the number of decoded frames for the selected serial bus.
Suffix:
<m>
.
1..4
Return values:
<Count> Range: 0 to 100000
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:DPHY:RESult:FRAMe<n>:CS?
Returns the checksum of the specified frame.
Protocols