Remote control commands
R&S
®
RTO6
1671User Manual 1801.6687.02 ─ 05
Usage: Asynchronous command
BUS<m>:SETReflevels
Executes the measurement of reference levels and sets the thresholds to the middle
reference level of the measured amplitude.
Suffix:
<m>
.
1..4
Selects the serial bus.
Usage: Event
Asynchronous command
BUS<m>:FAUToset
Starts software algorithms for determining the signal threshold levels and bitrate.
Suffix:
<m>
.
1..4
Usage: Event
Asynchronous command
BUS<m>:RESult <ShowResultTable>
Opens a table with decoded data of the serial signal. The function affects all protocol
types and requires the option for the analyzed protocol.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<ShowResultT
able> ON | OFF
*RST: ON
Usage: Asynchronous command
BUS<m>:THReshold <ShwThresLines>
If ON, the threshold levels are displayed in the diagram.
Suffix:
<m>
.
1..4
Selects the serial bus.
Parameters:
<ShwThresLines> ON | OFF
*RST: OFF
Usage: Asynchronous command