EasyManua.ls Logo

R&S RTO6 - 13.14.3 SpaceWire trigger; 13.14.3.1 SpaceWire trigger settings

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protocol analysis
R&S
®
RTO6
719User Manual 1801.6687.02 ─ 05
13.14.3 SpaceW
ire trigger
13.14.3.1
SpaceWire trigger settings
Access: [Bus] > "Shortcuts" tab > "Setup trigger"
Make sure that:
In the [Bus] > "Setup" tab:
The correct "Protocol" is selected.
The data sources of the serial bus are channel signals.
In the "Trigger" > "Setup" tab:
The "Trigger on" = "Single event"
The trigger "Source" = "Serial bus".
The correct "Serial bus" is selected.
Type
Selects the trigger type for the SpaceWire analysis.
"Control frame"
Sets the trigger to the selected control type frame.
"Data Pattern"
Sets the trigger to a defined data pattern or pattern range.
"NULL frame"
Sets the trigger to a null frame, a frame without usable data.
SpaceWire (option R&S RT
O6-K530)