Remote control commands
R&S
®
RTO6
1892User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:FLXRay:SYFRame <SearchName>,<SyncFrame>
SEARch:TRIGger:FLXRay:SYFRame
? <SearchName>
Searches for the sync frame used for synchronization of the FlexRay system. Only
sync nodes can send this frame type.
Parameters:
<SyncFrame>
ONE | ZERO | DC
Bit value: 1, 0, or X (don't care)
*RST: DC
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:SYMBol <SearchName>,<Symbol>
SEARch:TRIGger:FLXRay:SYMBol? <SearchName>
Searches for a symbol or for a wakeup pattern.
Parameters:
<Symbol> CASMts | WAKeup
CASMts
Collision Avoidance Symbol / Media access T
est Symbol. These
symbols are identical and can be sent in the optional symbol
window at the end of a communication cycle. They are used to
avoid collisions during the system start.
WAKeup
The wakeup pattern is sent to activate the nodes of the system.
*RST: CASMts
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:BSSerror <SearchName>,<BSSError>
SEARch:TRIGger:FLXRay:BSSerror?
<SearchName>
Searches for error in SyteStart Sequence. The BSS is transmitted before each byte.
Parameters:
<BSSError> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:FESerror <SearchName>,<FESError>
SEARch:TRIGger:FLXRay:FESerror? <SearchName>
Searches for error in Frame End Sequence. FES indicates the end of each frame.
Protocols