Remote control commands
R&S
®
RTO6
1891User Manual 1801.6687.02 ─ 05
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with SEARch:TRIGger:
FLXRay:
PMIN and SEARch:
TRIGger:FLXRay:PMAX.
*RST: OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:PMAX <SearchName>,<PayloadLengthTo>
SEARch:TRIGger:FLXRay:PMAX? <SearchName>
Sets the the end value of a payload length range if the condition SEARch:TRIGger:
FLXRay:PCONdition is set to INRange or OORange.
Parameters:
<PayloadLengthTo> Range: 0 to 127
Increment: 1
*RST: 0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:PMIN <SearchName>,<PayloadLength>
SEARch:TRIGger:FLXRay:PMIN? <SearchName>
Specifies a payload length - the number of words in the payload segment - or sets the
the start value of an payload length range. Information is transmitted in 2-byte words,
so the number of data bytes in the payload segment is twice the payload length.
Parameters:
<PayloadLength> Range: 0 to 127
Increment: 1
*RST: 0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:STFRame <SearchName>,<StartupFrame>
SEARch:TRIGger:FLXRay:STFRame
? <SearchName>
Searches for startup frames used for startup of the network. Only specific start nodes
can send this frame type.
Parameters:
<StartupFrame>
ONE | ZERO | DC
Bit value: 1, 0, or X (don't care)
*RST: DC
Parameters for setting and query:
<SearchName>
Protocols