I/Q software interface (Option R&S RTO6-K1
1)
R&S
®
RTO6
1067User Manual 1801.6687.02 ─ 05
Remote command:
TRIGger<m>:
NFC:BITRate
on page 2478
Event
Sets the trigger on:
NFC-A:
ALL_REQ or SENS_REQ command (polling requests)
NFC-B:
ALLB_REQ or SENSB_REQ command
NFC-F:
Start of sequence pattern with 48 bit or 96-bit length
Remote command:
TRIGger<m>:NFC:EVENt on page 2478
Trigger level
Sets the voltage level for the trigger condition. You can also drag the trigger level
marker on the display (TA or TB on the right edge of the display). The range of the trig-
ger level is limited in a way so that always a hysteresis for stable trigger conditions is
available.
Remote command:
TRIGger<m>:LEVel<n>[:VALue] on page 1391
NFC trigger