Loading...
Remote control commands
R&S
®
RTO6
1682User Manual 1801.6687.02 ─ 05
Parameters:
<UseAddress> ON | OFF
*RST: OFF
TRIGger<m>:I2C:ADOR<n>:ADRType <AddressType>
Sets the address type for the indicated ADOR address in the "address OR" trigger con-
dition.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<AddressT
ype> BIT7 | BIT7_RW | BIT10
*RST: BIT7
TRIGger<m>:I2C:ADOR<n>[:VALue] <Address>
Defines the address pattern of the indicated ADOR address in the "address OR" trigger
condition.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<Address> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page
1286.
TRIGger<m>:I2C:ADOR<n>:RWBit <RWBit>
Defines the R/W bit of the indicated ADOR address in the "address OR" trigger condi-
tion.
Suffix:
<n>
.
1..4
Index of the address in an "address OR" condition (OR slot)
Parameters:
<R
WBit> UNDefined | READ | WRITe | EITHer
UNDefined
Return value only
*RST: EITHer