Remote control commands
R&S
®
RTO6
1700User Manual 1801.6687.02 ─ 05
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:I2C:DMIN <SearchName>,<Data>
SEARch:TRIGger:I2C:DMIN? <SearchName>
Specifies the data bit pattern, or sets the the start value of a data pattern range.. Enter
the bytes in msb first bit order
. The maximum pattern length is 64 bit. W
aveform data is
compared with the pattern byte-by-byte.
Parameters:
<Data> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286.
Parameters for setting and query:
<SearchName>
Usage: Asynchronous command
SEARch:TRIGger:I2C:DMAX <SearchName>,<DataTo>
SEARch:TRIGger:I2C:DMAX
? <SearchName>
Sets the the end value of an address range if SEARch:TRIGger:I2C:DCONdition
is set to INRange or OORange.
Parameters:
<DataTo> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286.
Parameters for setting and query:
<SearchName>
Usage: Asynchronous command
SEARch:TRIGger:I2C:ADNack <SearchName>,<AddressNack>
SEARch:TRIGger:I2C:ADNack?
<SearchName>
Parameters:
<AddressNack> ON | OFF
*RST: ON
Parameters for setting and query:
<SearchName>
Usage: Asynchronous command
SEARch:TRIGger:I2C:DRNack <SearchName>,<DataReadNack>
SEARch:TRIGger:I2C:DRNack?
<SearchName>
Searches for the end of the read process when the master reads data from the slave.
This Nack is sent according to the protocol definition, it is not an error.
Protocols