Remote control commands
R&S
®
RTO6
1705User Manual 1801.6687.02 ─ 05
Query parameters:
<SearchName>
Return values:
<AddressType> BIT7 | BIT7_RW | BIT10 | AUTO | ANY
*RST: BIT7
Usage: Query only
SEARch:RESult:I2C:FRAMe<m>:ASTart? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<AddressStart> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s
Usage: Query only
SEARch:RESult:I2C:FRAMe<m>:DATA? <SearchName>
Returns the data bytes of the indicated frame.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<Data>
Usage: Query only
SEARch:RESult:I2C:FRAMe<m>:RWBStart? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<RWBitStart> Range: -100E+24 to 100E+24
Increment: 100E-12
*RST: 0
Default unit: s