Remote control commands
R&S
®
RTO6
1713User Manual 1801.6687.02 ─ 05
TRIGger<m>:SPI:DPTO...............................................................................................
1714
TRIGger<m>:SPI:
FCONdition....................................................................................... 1714
TRIGger<m>:SPI:MISopattern.......................................................................................1715
TRIGger<m>:SPI:MOSipattern...................................................................................... 1715
TRIGger<m>:SPI:TYPE <Type>
Selects the trigger type for SPI analysis.
Parameters:
<Type> SSACtive | TIMeout | MOSI | MISO | MOMI
SSACtive
Start of the message: slave select signal SS changes to the
active state.
TIMeout
T
riggers on the next message start after the "T
imeout" time.
MOSI
Triggers on a specified data pattern in that is expected on the
MOSI line. Define the pattern with TRIGger<m>:SPI:
MOSipattern.
MISO
Triggers on a specified data pattern in that is expected on the
MISO line. Define the pattern with TRIGger<m>:SPI:
MISopattern
MOMI
Triggers on a specified data patterns on the MISO and MISO
lines.
*RST: SSACtive
Usage: Asynchronous command
TRIGger<m>:SPI:PALignment <DataAlignment>
Defines how the specified data pattern is searched.
Parameters:
<DataAlignment> WORD | BIT
WORD
The pattern is matched only at word boundaries.
BIT
Bit-by bit: the pattern can be at any position in the data word.
*RST: WORD
Usage: Asynchronous command