Remote control commands
R&S
®
RTO6
1716User Manual 1801.6687.02 ─ 05
Return values:
<FrameData> Comma-separated sequence of integer values (N, L1, R1,…,
LN, RN). N is the number of word pairs in the frame, and {L1,R1}
…{LN,RN} are the value pairs. The values Lx and Rx are associ-
ated with the MOSI and the MISO channel, respectively
. If a
channel is disabled, an empty value is returned.
Example:
BUS:SPI:
FRAMe3:DATA?
<-- 2,
10,108,35,
70 (MOSI+MISO)
2,10,,35, (MOSI only)
2,,108,,70 (MISO only)
Usage: Query only
BUS<m>:SPI:FCOunt?
BUS<m>:SPI:FRAMe<n>:COUNt?
Returns the number of decoded frames.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Return values:
<Count> Total number of decoded frames.
Usage: Query only
BUS<m>:SPI:FRAMe<n>:BITRate?
Returns the primary bit rate.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<PrimaryBitRate> Range: 0 to 100000000000
Increment: 1
*RST: 0
Default unit: bps
Usage: Query only
BUS<m>:SPI:FRAMe<n>:STATus?
Returns the overall state of the specified frame.
Protocols