Remote control commands
R&S
®
RTO6
1897User Manual 1801.6687.02 ─ 05
Return values:
<Flags> Range: 0 to 255
Increment: 1
*RST: 0
Usage: Query only
SEARch:RESult:FLXRay:FRAMe<m>:PAYLength? <SearchName>
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<PayLen> Range: 0 to 127
Increment: 1
*RST: 0
Usage: Query only
SEARch:RESult:FLXRay:FRAMe<m>:STATus? <SearchName>
Returns the overall state of the selected frame.
Suffix:
<m>
.
*
Query parameters:
<SearchName>
Return values:
<State> OK | FSS | BSS | FES | INDicator | HCRCerror | CRCerr |
LENER | LENer | HCFCerror | INSufficient
OK: the frame is valid.
FSS: Frame Start Sequence after TSS is missing.
BSS: Byte Start Sequence is missing.
FES: error in the Frame End Sequence.
INDicator: Error in indicator bits.
HCRCerror: Header CRC is not valid.
CRCerr: Payload CRC is not valid.
LENER = LENer: Unexpected length of the frame.
HCFCerror: Header CRC error and frame CRC error
INSuf
ficient: The frame is not completely contained in the acqui-
sition. The acquired part of the frame is valid.
*RST: OK
Usage: Query only