Remote control commands
R&S
®
RTO6
1940User Manual 1801.6687.02 ─ 05
TRIGger<m>:CXPI:FID:MAX <FrameIDMax>
Sets the end value of a frame ID range if TRIGger<m>:
CXPI:
FID:CONDition is set
to INRange or OORange.
Suffix: 
<m>
.
1..3
Parameters:
<FrameIDMax>
TRIGger<m>:CXPI:FID:MIN <FrameIDMin>
Specifies a frame ID pattern, or sets the start value of a pattern range.
Suffix: 
<m>
.
1..3
Parameters:
<FrameIDMin>
TRIGger<m>:CXPI:NM <NM>
Sets the value of the network management (NM) field.
Suffix: 
<m>
.
1..3
Parameters:
<NM>
TRIGger<m>:CXPI:TYPE <Type>
Selects the trigger type for the CXPI analysis.
Suffix: 
<m>
.
1..3
Parameters:
<T
ype> STARt | NORMal | NPOLl | SLEEP | LONG | LPOLl | PID |
PTYPe | PTPD | ERRor
ST
ARt
Triggers on the STARt of the frame.
NORMal
Triggers on a NORMal frame. Optionally you can define a frame
ID condition, an NM, a CT, a DLC condition, a data pattern con-
dition and an index condition.
NPOLl
Triggers on a Normal POLL frame. Optionally you can define a
frame ID condition, an NM, a CT, a DLC condition, a data pattern
condition and an index condition.
Protocols