Remote control commands
R&S
®
RTO6
2234User Manual 1801.6687.02 ─ 05
ON
Checking condition enabled
OFF
Checking condition disabled
*RST: OFF
Parameters for setting and query:
<SearchName> String with the name of the search.
Example:
SEARch:TRIGger:USBPd:FRAMe3:FLD1:ENABle ON
Enables searching for the Extended field of the Control frame.
SEARch:TRIGger:USBPd:
FRENable "Data Frame",
"Data Role" ON
Enables searching for the Data Role field of the Data frame.
SEARch:TRIGger:USBPd:BIT <SearchName>,<Frame>, <Field>, <Bit>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:
BIT <SearchName>,<BitState>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:BIT? <SearchName>
Sets the bit state of a field to be searched that only consists of one bit.
Suffix:
<m>
.
*
Specifies the frame.
<n> *
Specifies the field number within the frame.
Parameters:
<BitState> ONE | ZERO | DC
ONE
1
ZERO
0
DC
"Don't care" = X
*RST: DC
Parameters for setting and query:
<SearchName> String with the name of the search.
SEARch:TRIGger:USBPd:DMAX <SearchName>,<Frame>, <Field>, <Data>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:
DMAX <SearchName>,<DataMax>
SEARch:TRIGger:USBPd:FRAMe<m>:FLD<n>:DMAX? <SearchName>
Sets the end value of a data pattern range if SEARch:TRIGger:USBPd:FRAMe<m>:
FLD<n>:DOPerator is set to INRange or OORange.
Suffix:
<m>
.
*
Specifies the frame.
Protocols