Remote control commands
R&S
®
RTO6
2279User Manual 1801.6687.02 ─ 05
TRIGger<m>:MPHY:LCCType <LCCT
ype>
Selects the type of LCC frame to be triggered on.
Suffix:
<m>
.
1..3
Parameters:
<LCCT
ype> ANY | SLEEP | STALL | READCAP | READMFG | READVEND |
WRITEATTR |
PWMG0 | PWMG1 | PWMG2 | PWMG3 |
PWMG4 | PWMG5 | PWMG6 | PWMG7 | HSG1A | HSG2A |
HSG3A | HSG4A | HSG1B | HSG2B | HSG3B | HSG4B |
RESERVED
ANY
All the available LCC commands.
SLEEP
Switches the power-saving state to ultra-low power. In this state,
up to 90% power saving is achieved.
STALL
Switches the power-saving state to ultra-low power. In this state,
up to 75% power saving is achieved.
READCAP
Recovers data about the OMC’s capabilities.
READMFG
Retrieves manufacturing ID and vendor-specific information.
READVEND
Retrieves the additional four delimited bytes containing vendor-
specific information.
WRITEATTR
Sets the configuration parameters required for lane operation.
PWMG0 | PWMG1 | PWMG2 | PWMG3 | PWMG4 | PWMG5 |
PWMG6 | PWMG7
Switches the transmission mode to the selected low-power gear.
HSG1A | HSG2A | HSG3A | HSG4A | HSG1B | HSG2B |
HSG3B | HSG4B
Switches the transmission mode to the selected high-speed
gear.
RESERVED
Reserved bit command. These bits are reserved for future use.
*RST: ANY