Remote control commands
R&S
®
RTO6
2362User Manual 1801.6687.02 ─ 05
BUS<m>:PCIE:RESult:PACKet<n>:FCOunt?
Returns the number of decoded fields in the selected packet.
Suffix:
<m>
.
1..4
<n> *
Return values:
<FieldCount> Range: 0 to 65535
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:PCIE:RESult:PACKet<n>:FLD<o>:FVAL?
Returns the formatted value of the field with the selected field number within the frame
with the selected packet number (for the selected serial bus).
Suffix:
<m>
.
1..4
<n> *
<o> *
Selects the field number
.
Return values:
<V
alueFormatted> String parameter
Usage: Query only
BUS<m>:PCIE:RESult:PACKet<n>:FLD<o>:STATus?
Returns the status of the frame with the selected field number within the packet with
the selected packet number (for the selected serial bus).
Suffix:
<m>
.
1..4
<n> *
<o> *
Selects the field number
.
Return values:
<State> OK |
MALF | CRC16 | ECRC | LCRC | LEN | POE | MEE |
UNCorrelated | FCRC |
FPERror | UNKNown | OUTRange |
INComplete | SYNCerror
MALF
Malformed packet
CRC16
CRC16 error
Protocols