Remote control commands
R&S
®
RTO6
2516User Manual 1801.6687.02 ─ 05
CDR:HARDware:SERStandard <SerialStandard>
Sets the serial standard. Set CUSTOM to adjust the bit rate and the bandwidth manually
.
Parameters:
<SerialStandard>
*RST:  CUSTOM
Usage:  Asynchronous command
CDR:HARDware:BREStimate
Estimates the bite rate once, for the current acquisition.
Usage:  Event
Asynchronous command
CDR:HARDware:BITRate <Bitrate>
Parameters:
<Bitrate> Range:  200E+3  to  2.5E+9 for 10 GSa/s; range depends
on sample rate
Increment:  10
*RST:  1E+9
Default unit: bps
Usage:  Asynchronous command
CDR:HARDware:ESLope <Edge>
Selects the edges of the data stream that are used for the clock recovery.
●
"Either": Both positive and negative edges are used
●
"Positive / Negative": Only one edge direction is used. Use one of these settings if
the other edge might deliver unreliable results.
Parameters:
<Edge> POSitive | NEGative | 
EITHer
*RST:  EITHer
Usage:  Asynchronous command
CDR:HARDware:PLL:ORDer <PLLOrder>
Sets the order of the PLL: first or second order. PLL of higher order can compensate
for more complex jitter behavior
.
Parameters:
<PLLOrder> FIRSt | SECond
*RST:  FIRSt
Usage:  Asynchronous command