Remote control commands
R&S
®
RTO6
2556User Manual 1801.6687.02 ─ 05
POWer:TRANsient:REPort:ADD
Adds the result to the report list.
Usage: Event
POWer:TRANsient:RESult[:ACTual]? <MeasT
ype>
Returns the results of the transient response measurement.
Query parameters:
<MeasT
ype> OVERshoot | RTIMe | DELay | PEAKtime | SETTling
Usage: Query only
POWer:TRANsient:SIGHigh <ExpHighOutputSignLev>
Sets the expected signal high voltage value.
Parameters:
<ExpHighOutputSignLev>Range: -1000 to 1000
Increment: 1E-3
*RST: 1
Default unit: V
POWer:TRANsient:SIGLow <ExpLowOutputSignLev>
Sets the expected signal low voltage value.
Parameters:
<ExpLowOutputSignLev>Range: -1000 to 1000
Increment: 1E-3
*RST: 0
Default unit: V
POWer:TRANsient:TRGChannel <TriggerSource>
Sets the source channel of the trigger.
Parameters:
<TriggerSource> CHAN1 | CHANnel1 | CHAN2 | CHANnel2 | CHAN3 |
CHANnel3 | CHAN4 | CHANnel4
CHAN1 = CHANnel1, CHAN2 = CHANnel2, CHAN3 = CHAN-
nel3, CHAN4 = CHANnel4
Only the measurement source channels can be used as trigger
source.
*RST
: CHAN1
Power analysis (option R&S RT
O6-K31)