The basic measurement settings are source, category, and the selection of the mea-
surement. Y
ou can refine the setup to get more specific results:
Gating
A gate limits the measurement to a user-defined part of the waveform. See Chap-
ter 8.2.3, "Measurement gates"
, on page 304.
Statistics and long term measurements
To evaluate time-dependent behavior of measurement results, you can use statis-
tics, long term measurements, and tracks. You can also decide, how many mea-
surement results per acquisition contribute to the calculation. See: Chapter 8.2.12,
"Result analysis", on page 355.
Limit checks and actions on test result
Limit and margin checks evaluate if the measurement result exceeds a specified
value. You can define actions that are performed on limit or margin violation. See:
Chapter 8.2.13, "Limit and margin checks", on page 363.
Measurement categories
The various measurement are grouped in several categories. The category defines
which sources can be analyzed.
Time domain:
Amp/Time: amplitude and time measurements
Eye: eye diagram measurements
Histogram: measurements on histograms
Jitter measurements (available if one of the jitter options is installed)
Protocol: available for audio signals (option R&S RTO6-K510)
Protocol: advanced analysis (available if option R&S RTO6-K500 is installed)
Frequency domain
Spectrum: measurements on spectrum waveforms
Histogram: measurements on histograms
Details on automatic measurements are described in the following chapters:
Measurement setup in general..............................................................................297
Measurement results.............................................................................................301
Measurement gates.............................................................................................. 304
Reference levels................................................................................................... 307
Amplitude/time measurements..............................................................................316
Eye diagram measurements................................................................................. 330
Spectrum measurements......................................................................................334
Histograms and histogram measurements........................................................... 340
Jitter measurements..............................................................................................347
Optical measurements.......................................................................................... 348
Protocol measurements (option R&S RTO6-K500).............................................. 349
Result analysis......................................................................................................355
Limit and margin checks....................................................................................... 363
Automatic measurements

Table of Contents

Other manuals for R&S RTO6

Related product manuals