Protocol analysis
R&S
®
RTO6
490User Manual 1801.6687.02 ─ 05
Command lines
Command lines define the version of the PTT file and the protocol name:
@FILE_VERSION: must appear exactly once in the file
@PROT
OCOL_NAME: must appear at least once in the file. Thus, one file can
contain several label lists for dif
ferent protocols.
# --- Start of PTT file
@FILE_VERSION = 1.0
@PROTOCOL_NAME = i2c
[... Label list for I2C]
@PROTOCOL_NAME = can
[... Label list for CAN]
# --- End of PTT file
Standard lines
Standard lines define the contents of the label list. The rules for standard lines follow
the csv convention, they are:
Values are separated by commas
Space characters following a delimiter are ignored
Values with a special character (comma, newline, or double quote) must be
enclosed in double quotes
Text in double quotes must be escaped by double quote characters
The format of the numeric value is indicated by a suffix. The following formats are sup-
ported:
Format Suffix Example
Decimal <empty>
d
106, DeviceName
106d,
DeviceName
Hexadecimal h
6Ah, DeviceName
or prefix:
0x6A, DeviceName
Octal o
152o, DeviceName
Binary b
01101010b, DeviceName
The maximum supported word size for (unsigned) integers is 64 bits.
# --- Start of PTT file
@FILE_VERSION = 1.0
@PROTOCOL_NAME = i2c
# Following two lines are equal:
7,01h,Temperature
7,01h, Temperature
# A comma must be enclosed in double quotes:
7,01h,"Temperature, Pressure, and Volume"
# A double quote must also be enclosed in double quotes:
7,7Fh,"Highspeed ""Master"" 01"