Protocol analysis
R&S
®
RTO6
797User Manual 1801.6687.02 ─ 05
1000BASE-T1 Specific Label Settings
Label lists are protocol-specific. Label lists for 1000BASE-T1 are available in CSV and
PTT format.
A 1000BASE-T1 label file contains two values for each ethernet header:
Ethernet header display
Symbolic label: name of the address, specifiing its function in the bus network.
Decode layer
Selects the decode layer
.
Decoding is performed in several steps, and the end results are presented in the
decode table. The decode layer selects an interim step for which the decoding result is
shown in the honeycomb display
.
"Off"
No decode layer is displayed.
"Ternary sym-
bols"
Decoded ternary symbols.
"Scrambled
bits"
Scrambled ternary bits.
"Descrambled
bits"
Descrambled ternary bits.
"Corrected RS-
FEC symbols"
Displays RS-FEC symbols that have been corrected.