Power analysis (option R&S RTO6-K31)
R&S
®
RT
O6
1149User Manual 1801.6687.02 ─ 05
In the "Settings" tab, you configure the current harmonic measurement parameters and
display settings.
Standard in use
Select the standard in use. For a list of the available standards, see Table 19-1.
T
able 19-1: Current Harmonic pre-compliance standards
Standard Application
EN 61000-3-2 Class A Balanced 3-phase equipment, household appliances
(excluding equipment identified as class D), tools
(excluding portable tools), dimmers for incandescent
lamps, audio equipment
EN 61000-3-2 Class B Portable tools, not professional arc welding equip-
ment
EN 61000-3-2 Class C Lighting equipment
EN 61000-3-2 Class D PC, PC monitors, radio, or TV receivers with an
input power less than or equal to 600W
MIL-STD-1399 Military shipboard user equipment
RTCA DO-160 Environmental tests of avionics hardware
Remote command:
POWer:HARMonics:
STAN on page 2533
Input