Remote control commands
R&S
®
RTO6
1373User Manual 1801.6687.02 ─ 05
ZVC:Z<m>:V<n>:BANDwidth?
Queries the bandwidth of the voltage channel. Y
ou can set the probe bandwidth with
ZVC:BANDwidth.
Suffix:
<m>
.
1..2
<n> 1..4
Return values:
<Bandwidth>
Range: 5000 to 1E+6
Increment: 5000
*RST: 1E+6
Default unit: Hz
Usage: Query only
Asynchronous command
ZVC:Z<m>:V<n>:IMPedance <MeasImp>
Sets the voltage impedance of the probe channel for power calculations and measure-
ments.
Suffix:
<m>
.
1..2
<n> 1..4
Parameters:
<MeasImp> Range: 1 to 100E+3
Increment: 1
*RST: 50
Default unit: Ω
Usage: Asynchronous command
ZVC:Z<m>:V<n>:OFFSet <VerticalOf
fset>
Sets the vertical offset for the voltage channel.
Suffix:
<m>
.
1..2
<n> 1..4
Parameters:
<VerticalOffset> Range: -1 to 1
Increment: 0.01
*RST: 0
Default unit: V
Usage: Asynchronous command