Remote control commands
R&S
®
RTO6
1609User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:GLITch:POLarity................................................................................
1609
SEARch:TRIGger:GLIT
ch:RANGe................................................................................. 1609
SEARch:TRIGger:GLITch:WIDTh...................................................................................1609
SEARch:TRIGger:GLITch:POLarity <SearchName>,<Polarity>
SEARch:TRIGger:GLITch:POLarity? <SearchName>
Indicates the polarity of a pulse, that is the direction of the first pulse slope.
Parameters:
<Polarity> POSitive | NEGative | EITHer
See Chapter 24.4.4, "Polarity parameter", on page 1285.
*RST
: POSitive
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:TRIGger:GLITch:RANGe <SearchName>,<RangeMode>
SEARch:TRIGger:GLITch:
RANGe? <SearchName>
Selects which glitches are identified: shorter or longer than the specified width (see
SEARch:TRIGger:GLITch:WIDTh on page 1609).
Parameters:
<RangeMode> SHORter | LONGer
*RST: SHORter
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:TRIGger:GLITch:WIDTh <SearchName>,<Width>
SEARch:TRIGger:GLITch:
WIDTh? <SearchName>
Sets the length of a glitch. The instrument triggers on pulses shorter or longer than this
value (see also SEARch:TRIGger:GLITch:RANGe on page 1609).
You need to know the expected pulse widths of the circuit to set the glitch width cor-
rectly.
Parameters:
<Width> Range: 100E-12 to 1E-3
Increment: 100E-6
*RST: 1E-9
Default unit: s
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
Search