EasyManua.ls Logo

R&S RTO6 - Page 1633

R&S RTO6
2677 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTO6
1633User Manual 1801.6687.02 ─ 05
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:GATE:RELative:STARt <SearchName>,<RelativeStart>
SEARch:GATE:RELative:ST
ARt? <SearchName>
Defines the starting value for the gate.
Parameters:
<RelativeStart> Range: 0 to 100
Increment: 0.1
*RST: 0
Default unit: %
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:GATE:RELative:STOP <SearchName>,<RelativeStop>
SEARch:GA
TE:RELative:ST
OP? <SearchName>
Defines the end value for the gate.
Parameters:
<RelativeStop> Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: %
Parameters for setting and query:
<SearchName> Search definition
Usage: Asynchronous command
SEARch:GATE:ZCOupling <SearchName>,<ZoomCoupling>
SEARch:GATE:ZCOupling
? <SearchName>
If enabled, the gate area is set to the limits of a zoom area.
The zoom diagramm is selected using SEARch:GATE:ZDIagram.
Parameters:
<ZoomCoupling> ON | OFF
*RST: OFF
Parameters for setting and query:
<SearchName> String with the name of the search
Usage: Asynchronous command