Remote control commands
R&S
®
RTO6
1680User Manual 1801.6687.02 ─ 05
Parameters:
<RWBitAddress> READ | WRITe | EITHer
EITHer
T
ransfer direction is not relevant.
*RST
: EITHer
Usage: Asynchronous command
TRIGger<m>:I2C:ADNack <AddressNack>
Triggers if the address acknowledge bit is missing - no slave recognizes the address.
Parameters:
<AddressNack>
ON | OFF
*RST: ON
Usage: Asynchronous command
TRIGger<m>:I2C:DWNack <DataWriteNack>
T
riggers if a date acknowledge bit is missing - the addressed slave does not accept the
data.
Parameters:
<DataWriteNack> ON | OFF
*RST: ON
Usage: Asynchronous command
TRIGger<m>:I2C:DRNack <DataReadNack>
Triggers on the end of the read process when the master reads data from the slave.
This Nack is sent according to the protocol definition, it is not an error
.
Parameters:
<DataReadNack> ON | OFF
*RST: ON
Usage: Asynchronous command
TRIGger<m>:I2C:AMODe <AddressT
ype>
Sets the address length. The setting af
fects the address input with TRIGger<m>:I2C:
ADDRess and TRIGger<m>:I2C:ADDTo.
Parameters:
<AddressType> BIT7 | BIT7_RW | BIT10 | ANY
BIT7
Enter the 7 address bits. Only available if BUS<m>:I2C:RWBit
SEParate is set.