Remote control commands
R&S
®
RTO6
1855User Manual 1801.6687.02 ─ 05
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:IMIN <SearchName>,<IdPattern>
SEARch:TRIGger:LIN:IMIN? <SearchName>
Specifies a slave identifier pattern, or sets the the start value of an identifier range.
Parameters:
<IdPattern> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:IMAX <SearchName>,<IdPatternTo>
SEARch:TRIGger:LIN:IMAX?
<SearchName>
Sets the the end value of an identifier range if SEARch:TRIGger:LIN:ICONdition
is set to INRange or OORange.
Parameters:
<IdPatternTo> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286.
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:IDOR<m>:ENABle <SearchName>,<UseIdentifier>
SEARch:TRIGger:LIN:IDOR<m>:ENABle? <SearchName>
Includes the indicated IDOR address in the "identifier OR" search.
Suffix:
<m>
.
1..4
Index of the identifier in an "identifier OR" condition
Parameters:
<UseIdentifier>
ON | OFF
*RST: OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:LIN:IDOR<m>[:VALue] <SearchName>,<IdPattern>
SEARch:TRIGger:LIN:IDOR<m>[:VALue]? <SearchName>
Defines the pattern of the indicated IDOR identifier in the "identifier OR" trigger condi-
tion.