Return values:
<Count> Returns the number of decoded frames.
Range: 0 to 100000
Increment: 1
*RST: 0
Usage: Query only
BUS<m>:FLXRay:FRAMe<n>:STATus?
Returns the overall state of the selected frame.
Suffix:
<m>
.
1..4
Selects the serial bus.
<n> *
Selects the frame.
Return values:
<FrameState> OK | FSS | BSS | FES | INDicator | HCRCerror | CRCerr |
LENER | LENer | HCFCerror | INSuf
ficient
OK: the frame is valid.
FSS: Frame Start Sequence after TSS is missing.
BSS: Byte Start Sequence is missing.
FES: error in the Frame End Sequence.
INDicator: Error in indicator bits.
HCRCerror: Header CRC is not valid.
CRCerr: Payload CRC is not valid.
LENER = LENer: Unexpected length of the frame.
HCFCerror: Header CRC error and frame CRC error
INSuf
ficient: The frame is not completely contained in the acqui-
sition. The acquired part of the frame is valid.
*RST: OK
Usage: Query only
BUS<m>:FLXRay:FRAMe<n>:STARt?
BUS<m>:FLXRay:FRAMe<n>:ST
OP?