Remote control commands
R&S
®
RTO6
1952User Manual 1801.6687.02 ─ 05
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CXPI:FID:MAX <SearchName>,<FrameIDMax>
SEARch:TRIGger:CXPI:FID:MAX? <SearchName>
Sets the end value of a frame ID range if SEARch:
TRIGger:
CXPI:FID:CONDition
is set to INRange or OORange.
Parameters:
<FrameIDMax>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CXPI:FID:MIN <SearchName>,<FrameIDMin>
SEARch:TRIGger:CXPI:FID:MIN? <SearchName>
Specifies a frame ID pattern, or sets the start value of a pattern range.
Parameters:
<FrameIDMin>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CXPI:NM <SearchName>,<NM>
SEARch:TRIGger:CXPI:NM? <SearchName>
Sets the value of the network management (NM) field.
Parameters:
<NM>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CXPI:TYPE <SearchName>,<T
ype>
SEARch:TRIGger:CXPI:TYPE?
<SearchName>
Searches for the selected CXPI frame type.
Parameters:
<Type> STARt | NORMal | NPOLl | SLEEP | LONG | LPOLl | PID |
PTYPe | PTPD | ERRor
ST
ARt
Triggers on the STARt of the frame.
NORMal
Triggers on a NORMal frame. Optionally you can define a frame
ID condition, a NM, a CT, a DLC condition, a data pattern condi-
tion and an index condition.