SEARch:TRIGger:MPHY:LWONe:CONDition <SearchName>,<CondOperator>
SEARch:TRIGger:MPHY
:L
WONe:CONDition? <SearchName>
Sets the condition for WORD 1. You can define an exact value or a value range.
Parameters:
<CondOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one pattern to
be set with the corresponding SEARch:
TRIGger:MPHY:
LWONe:MIN command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with SEARch:TRIGger:MPHY:LWONe:MIN and
SEARch:TRIGger:MPHY:LWONe:MAX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:LWONe:MIN <SearchName>,<LCCWORD1Min>
SEARch:TRIGger:MPHY:L
WONe:MIN? <SearchName>
Specifies the WORD 1 pattern, or sets the the start value of a pattern range.
Parameters:
<LCCWORD1Min> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:LWONe:MAX <SearchName>,<LCCWORD1Max>
SEARch:TRIGger:MPHY:L
WONe:MAX? <SearchName>
Sets the end value of the WORD 1 range if SEARch:TRIGger:MPHY:LWONe:
CONDition is set to INRange or OORange.
Parameters:
<LCCWORD1Max> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>