Remote control commands
R&S
®
RTO6
2309User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:MPHY:FSNumber:MAX <SearchName>,<FSNMax>
SEARch:TRIGger:MPHY
:FSNumber:MAX?
<SearchName>
Sets the end value of the FSN range if SEARch:TRIGger:MPHY:FSNumber:
CONDition is set to INRange or OORange.
Parameters:
<FSNMax> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:CRC:CONDition <SearchName>,<CRCOperator>
SEARch:TRIGger:MPHY
:CRC:
CONDition? <SearchName>
Sets the condition for CRC. You can define an exact value or a value range.
Parameters:
<CRCOperator> EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with the corresponding SEARch:
TRIGger:MPHY:
CRC:MIN command.
INRange | OORange
In range/Out of range: set the minimum and maximum value of
the range with SEARch:TRIGger:MPHY:CRC:MIN and
SEARch:TRIGger:MPHY:CRC:MAX.
*RST: EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MPHY:CRC:MIN <SearchName>,<CRCMin>
SEARch:TRIGger:MPHY:CRC:
MIN? <SearchName>
Specifies the CRC bit pattern, or sets the start value of a pattern range.
Parameters:
<CRCMin> Numeric or string pattern, see Chapter 24.4.6, "Bit pattern
parameter", on page 1286. The string parameter accepts the bit
value X (don't care).
Parameters for setting and query:
<SearchName>
Protocols