Remote control commands
R&S
®
RTO6
2338User Manual 1801.6687.02 ─ 05
TRIGger<m>:EBTB:SYME <Expression>
Selects the format of the symbol to be triggered on, if TRIGger<m>:
EBTB:
SSTYpe is
set to EXPRession.
Parameters:
<Expression>
TRIGger<m>:EBTB:SYMType <SymbolType>
Selects the data character (Dx.y) or control character to bea triggered on. Y
ou can
specify he value of the data character to be triggered on with TRIGger<m>:EBTB:DX
and TRIGger<m>:EBTB:DY.
Parameters:
<SymbolType> DXY | K280 | K281 | K282 | K283 | K284 | K285 | K286 | K287 |
K237 | K277 | K297 | K307
*RST: K285
TRIGger<m>:EBTB:TBPA <TBPattern>
Sets the 10-bit pattern to be triggered on, if TRIGger<m>:EBTB:STYPe
is set to TB.
Parameters:
<TBPattern>
TRIGger<m>:EBTB:STYPe <Type>
Selects the type of condition to be triggered on for 8b10b.
Parameters:
<T
ype> KD | EB | TB | EXPRession | ERRor
KD: K/D symbol
EB: 8-bit pattern
TB: 10-bit pattern
*RST: KD
TRIGger<m>:EBTB:UNK <UnkError>
Defines, if a trigger on a unknown symbol error is activated or not.
Parameters:
<UnkError> ON | OFF
*RST: OFF