Remote control commands
R&S
®
RTO6
2377User Manual 1801.6687.02 ─ 05
SEARch:TRIGger:PCIE:TLP:CFGT <SearchName>,<CfgT
ype>
SEARch:TRIGger:PCIE:TLP:CFGT? <SearchName>
Sets the configuration type to be searched for in the transaction layer type.
Parameters:
<CfgT
ype> ANY | TYPE0 | TYPE1
*RST: ANY
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:PCIE:TLP:CPID <SearchName>,<TLPCompleterID>
SEARch:TRIGger:PCIE:TLP:CPID? <SearchName>
Sets the completer ID to be searched for in the transaction layer type.
Parameters:
<TLPCompleterID> 16-bit pattern, see Chapter 24.4.6, "Bit pattern parameter",
on page 1286. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:PCIE:TLP:CPLS <SearchName>,<CplStatus>
SEARch:TRIGger:PCIE:TLP:CPLS? <SearchName>
Sets the completion status to be searched for in the transaction layer type.
Parameters:
<CplStatus> ANY | SUCCESS | UNSUPPORTED | RETRY | ABORT
*RST: ANY
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:PCIE:TLP:DEID <SearchName>,<TLPDeviceID>
SEARch:TRIGger:PCIE:TLP:DEID? <SearchName>
Sets the device ID to be searched for in the transaction layer type.
Parameters:
<TLPDeviceID> 16-bit pattern, see Chapter 24.4.6, "Bit pattern parameter",
on page 1286. The string parameter accepts the bit value X
(don't care).
Parameters for setting and query:
<SearchName>