In the "Setup" tab, you select the reference waveform and its source. The source can
be an active waveform - trace of an input channel, math waveform or another refer-
ence waveform - or a stored waveform.
R1/2/3/4.......................................................................................................................252
Show........................................................................................................................... 252
Signal.......................................................................................................................... 252
└ Source...........................................................................................................252
└ Update.......................................................................................................... 252
File.............................................................................................................................. 253
Clear............................................................................................................................253
R1/2/3/4
Each tab contains the settings for one of the four available reference waveforms.
Show
Displays the reference waveform in the diagram.
Remote command:
REFCurve<m>:STATe on page 1447
Signal
Selects a signal as the reference waveform.
Source ← Signal
Selects the source waveform from the active waveforms of input channels, math sig-
nals and other reference waveforms.
Remote command:
REFCurve<m>:SOURce on page 1446
Update ← Signal
Copies the selected source waveform with all its settings to the memory of the refer-
ence waveform. If the acquisition is running, the reference waveform is a snapshot.
Reference waveforms