Protocol analysis
R&S
®
RTO6
701User Manual 1801.6687.02 ─ 05
Subaddress / Mode setup: Condition, Subaddress min, Subaddress max
The subaddress/mode setup consists of the condition and one or two subaddress/
mode patterns.
The subaddress/mode setup settings are the same as in the MIL trigger setup, see
"Subaddress/ Mode
"
 on page 695.
Remote command: 
SEARch:TRIGger:MILStd:CMD:SCONdition on page 1976
SEARch:TRIGger:MILStd:CMD:SMIN on page 1976
SEARch:TRIGger:MILStd:CMD:SMAX on page 1977
Data word count / Mode code setup: Condition, Word count min, Word count
max
The data word count/mode code setup consists of the condition and one or two pat-
terns.
The subaddress/mode setup settings are the same as in the MIL trigger setup, see
"Data Word Count/Mode Code" on page 695.
Remote command: 
SEARch:TRIGger:MILStd:CMD:CCONdition on page 1976
SEARch:TRIGger:MILStd:CMD:CMIN on page 1976
SEARch:TRIGger:MILStd:CMD:CMAX on page 1977
T/R (Transmit/receive)
Specifies the data direction of the selected command.
For details, see "T/R (Transmit/receive)" on page 696.
Remote command: 
SEARch:TRIGger:MILStd:CMD:TR on page 1978
Status flags setup
Specifies the values (X, 0, 1) of the status flags.
The status flags setup settings are the same as in the MIL trigger setup, see "Status
Flags" on page 696.
Remote command: 
SEARch:TRIGger:MILStd:STATus:BCReceived on page 1979
SEARch:TRIGger:MILStd:STATus:BUSY on page 1979
SEARch:TRIGger:MILStd:STATus:DBCaccept on page 1979
SEARch:TRIGger:MILStd:STATus:INSTrument on page 1979
SEARch:TRIGger:MILStd:STATus:MERRor on page 1979
SEARch:TRIGger:MILStd:STATus:SREQuest on page 1979
SEARch:TRIGger:MILStd:STATus:SUBSystem on page 1979
SEARch:TRIGger:MILStd:STATus:TERMinal on page 1979
Error Condition
Selects the error type to be searched for. You can select one or more error types as
search condition.
The error types are the same as in the MIL trigger setup, see "Error Condition"
on page 696
MIL-1553 (option R&S RT
O6-K530)